Particle Counter

Liquid-borne Particle Counters

Print This Page

Font Size:

  • S
  • M
  • L

Liquid-borne Particle Counters

For measuring batch samples

  • KS-41B

    Particle Sensor、For resist

    Minimum measurable particle diameter 0.1μm
    Rated flow 5mL/min
    Maximum particle number concentration 9,600 particles/mL (coincidence loss 10%)
  • KS-41A

    Particle Sensor、For resist

    Minimum measurable particle diameter 0.15μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-19F

    Particle Sensor

    Minimum measurable particle diameter 0.03μm
    Rated flow 10mL/min
    Maximum particle number concentration 40,000 particles/mL (coincidence loss 10%)
  • KS-18FX

    Particle Sensor

    Minimum measurable particle diameter 0.04μm
    Rated flow 10mL/min
    Maximum particle number concentration 30 000 particles/mL (coincidence loss 10%)
  • KS-18F

    Particle Sensor

    Minimum measurable particle diameter 0.05μm
    Rated flow 10mL/min
    Maximum particle number concentration 30,000 particles/mL (coincidence loss 10%)
  • KS-42A

    Particle Sensor

    Minimum measurable particle diameter 0.1μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-42AF

    Particle Sensor

    Minimum measurable particle diameter 0.1μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-42B

    Particle Sensor

    Minimum measurable particle diameter 0.2μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-42BF

    Particle Sensor

    Minimum measurable particle diameter 0.2μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-42C

    Particle Sensor

    Minimum measurable particle diameter 0.5μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-42D

    Particle Sensor

    Minimum measurable particle diameter 2μm
    Rated flow 25mL/min
    Maximum particle number concentration 10,000 particles/mL (coincidence loss 10%)

For inline measurement

  • KL-30B

    Particle Counter, For pure water, Printer supplied

    Minimum measurable particle diameter 0.05μm
    Rated flow Flow rate 10mL/min and purge flow rate 0.1 to 1L/min combined (Purge flow rate will differ depending on sample fluid pressure)
    Maximum particle number concentration 200,000 particles/mL (coincidence loss 10%)
  • KL-30AX

    Particle Counter, For pure water, Printer supplied

    Minimum measurable particle diameter 0.04μm
    Rated flow Flow rate 20mL/min and purge flow rate 0.1 to 1L/min combined (Purge flow rate will differ depending on sample fluid pressure)
    Maximum particle number concentration 15,000 particles/mL (coincidence loss 10%)
  • KL-28BF

    Particle Counter

    Minimum measurable particle diameter 0.2μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KL-28B

    Particle Counter

    Minimum measurable particle diameter 0.2μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-16F

    Particle Sensor

    Minimum measurable particle diameter 0.1μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-16

    Particle Sensor

    Minimum measurable particle diameter 0.1μm
    Rated flow 10mL/min
    Maximum particle number concentration 1,200 particles/mL (coincidence loss 5%)
  • KS-17B

    Particle Sensor, For pure water

    Minimum measurable particle diameter 0.05μm
    Rated flow 10mL/min
    Maximum particle number concentration 100,000 particles/mL (coincidence loss 5%)
  • KL-30A

    Particle Counter, For pure water, Printer supplied

    Minimum measurable particle diameter 0.05μm
    Rated flow Flow rate 20mL/min and purge flow rate 0.1 to 1L/min combined (Purge flow rate will differ depending on sample fluid pressure)
    Maximum particle number concentration 15,000 particles/mL (coincidence loss 10%)

For pharmaceutical Products

  • KL-04A

    Light obscuration Partile Counter

    Minimum measurable particle diameter 1.3μm
    Rated flow 25mL/min