| Syringe Sampler KZ-30W1/KZ-30W2 (with CE marking) |
| Up to 50 sets of parameter settings can be stored in Purge or Measurement
mode |
 |
- Choice of three operation modes: purge mode, measurement mode, and combination
mode for preset sequence of purge and measurement operations.
- Memory for up to 50 sets of parameter settings for purge mode or measurement
mode.
- Selectable blank volume lets sample fluid flow rate stabilize after start
of plunger action.
- Syringe set with integrated valve for easy replacement.
- Automatic syringe capacity detection.
- When the KZ-30W1/KZ-30W2 is used together with the Rion liquid-borne particle
counter KL-11 etc., changing a setting that is common to both units (sample
flow rate, blank volume, number of measurement cycles in the measurement
mode) at one unit will automatically cause a change at the other unit as
well, so that the setup of both units is matched.
- The syringe sampler KZ-30W2 is in conformity with the European Union's
CE Compliance requirements.
|
| Specifications |
| Counters, sensors and syringe size can be connected |
| Counters and sensors |
KL-11, KL-11A, KL-20A, KL-22, KL-26, KL-27(with some limits regarding usable
functions)
KS-40/40A/40AF/41, KE-40/40AKE-40 (with some limits regarding usable functions) |
| Syringe size |
25 mL PP syringe set (standard)
25 mL Pylex glass syringe set (option)
10 mL Pylex glass syringe set (option) |
 |
| Material of parts in contact with sample fluid: |
Material of parts in contact with sample fluid: |
| Suitable sample fluids: |
Fluids which do not cause corrosion of fluid-contacting parts |
 |
|
| Operation stroke |
| Full stroke |
66mm |
| Tolerance |
60mm±2% |
| Repeat precision |
0.5% or less |
| Resolution |
0.6mm |
| Purge mode/Measurement mode |
| Flow rate |
| Setting range: |
10 to 100mL/min (with 25 mL syringe set) |
|
5 to 50mL/min (with 10 mL syringe set) |
| Resolution: |
1mL/min |
|
| Purge/Measurement volume |
| Setting range: |
0 to syringe capacity |
| Resolution: |
1/100 of syringe capacity |
|
| Measurement blank volume |
0 - 1/2.5 of syringe capacity
(Measurement volume + Blank volume < 1.1X syringe capacity) |
| Repeat setting |
1to 99 |
| Combination mode |
| Number of steps: |
1 to 10 |
| Number of memory addresses: |
50 (with battery backup) |
| Combination mode memory: |
1 (with battery backup) |
 |
| Power Supply |
AC100-240 V, 50/60 Hz, Approx. 100 VA |
| Back-up Battery |
maxell SUPER Lithium ( model ER17-33 ) |
| Dimensions and Weight |
Approx. 147 (W) X 350 (H) X 290 (D) mm, Approx. 6 kg |
|
|
| External Pressure Sampler KZ-30U/KZ-30MB |
| For off-line measurement, Sampler with pressure chamber |
 |
Particle counters can be connected:
KL-20, KL-20A, KL-21, KL-22, KL-26 and KL-27
- The simple chemical-proof sampler, KZ-30U is designed to pressurize and supply sample fluid to the particle counters for off-line measurement.
- Easy-to-operate chemical resistance sampler with chamber
- When the pressure in the chamber is too high, exhaust the air in the chamber
to prevent the malfunction.
- Specifications
-
| Maximum allowable input air pressure |
Sample air inlet: 0.4 MPa (gauge pressure)
Chamber: 0.2 MPa (gauge pressure) |
| Adjustable pressure range: |
0.02 to 0.2 MPa (gauge pressure) |
| Maximum allowable valve pressure: |
0.3 MPa (gauge pressure) |
| Material of parts in contact with sample fluid: |
PFA, PTFE, CTFE |
| Material of chamber: |
Pyrex glass (Inner surface is Teflon coated.),
SUS316, PP,
Chloroprene rubber |
| Dimensions and weight |
674 (H) X 250 (W) X 400 (D) mm, Approx. 15 kg |
|
|
| Sampler using Dropping method KZ-30M3 |
| Measurement for coarse particles and particles with high gravitation sedimentation velocity |
|
Suitable models :KL-11, KS-60 series
- For the measurement of particles with large size and high specific gravity
which does not come in the sensor by usual forcing up method. Because their
sedimentation velocity is too much high.
- The sample fluid comes in through the funnel on the sensor. Measurement
is carried out while the particles are falling.
- Specifications
-
| Sampling |
Dropping method |
| External pump |
KZ-28M1 |
|
|
| Super Bellows Pump K9904 |
| Supply sample fluid to particle counters without fluid leaks or contamination |
|
This pump is designed for supplying sample fluid to liquid-borne particle
counters. Because the pump uses the bellows principle, it has no plunger
which could lead to fluid leaks or produce contamination.
Five different measurement modes are possible, to fit the requirements of various system configurations.
|
| Pump Specifications |
| Pump principle |
Bellows |
| Sample object |
Photoresist, pure water, chemical fluids (no volatile fluids) |
| Max. exhaust volume |
15 mL/stroke |
| Max. exhaust capacity |
0.2 Mpa |
| Allowable fluid pressure |
0.3 MPa |
| Min. fluid viscosity |
30cp |
| Weight |
3.2 kg |
| Controller Specifications |
| Operation start |
Auto start, manual start (pump only) |
| Intake rate switching |
2 steps: purge and measurement |
| Connectors |
RS-232C-1, RS-232C-2, DATA LINK-1 X 2, DATA LINK-2, EXT CTRL-1, EXT CTRL-2,
PUMP 1,2,3 (1 unit only) |
| Pump connection cable length |
Standard 1.5m, maximum 10 m |
| Power requirement |
100 to 120 VAC |
| Dimensions |
266.5 (W) X 181.5 (H) X 89.5 (D) mm (max.) |
|
|
| Flow controller CVR-PVC (for DI-water), CVR-1/4-FM (for Chemical solution) |
| Flow controller for in line measurement |

CVR-1/4-FM
(Mass flow controller + Mass flow meter)

CVR-1/4-3
(Mass flow controller) |
CVR-PVC and CVR-1/4-FM are flow controllers for Liquid-borne particle counter.
They are located downstream of the counter in pressure line. They are made
by SURPASS.
CVR-1/4-FM Specifications
-
| Sample flow rate |
8 to 15 mL/min |
| Connection |
PT1/4 |
| Materials of parts exposed to sample fluid |
PTFE, PCTFE, High-purity Ceramic (SiC) |
| Allowable sample fluid temperature |
10 to 70 C |
| Allowable sample fluid pressure |
0.1 to 0.4 MPa, Max: 0.5 MPa |
|
|
| Portable Recirculation Filtration Unit MINIBOY<CHEMIBOY> |
| Cleaning of Particle Counter and easy blank check |
 |
| Pump: |
IWAKI MDG-M2S100 |
| Joint: |
KURABO K fitter |
| Tube fitting: |
KURABO |
| Valve: |
Two-way tap 2C-30B |
| Filter: |
Mitsubishi Chemical CS09DN (one example) |
| Case material |
acrylic |
- Specifications
-
| Dimensions |
40(W) X 29(H) X 15 (D)cm |
| Power supply |
AC100V+/-10% 50/60 Hz. 0.5 A |
|
|
| ●Chemical Solution Recirculation Filtration Unit CHEMIBOY |
| Recirculate and filtrate the sample fluid to maintain its cleanliness and
supply it to the particle counter |
| Specifications |
| Main unit material |
stainless steel |
| Material of parts in contact with sample fluid |
PTFE, PFA, PP, polyolefin, SUS316 |
| Max. filtrate particle size |
0.09micorn m |
| Max. flow rate |
8 L/mine |
| Max allowable pressure |
3.0 Kgf/cm2 |
| Temperature for operation |
20C |
| Dimensions and weight |
350(W) X 250 (H) X 250 (D) mm, 10 kg |
|
|
| Concentrations-standard fluid CLINTEX |
| An exclusive, concentrations-standard suspension of a size-standard particle
for calibration management |
 |
- Monodispersed PSL suspension by 1000 particles/mL
- Accuracy of particle size and its distribution;
accuracy of size: Indicated value +/- 3%
- On-site checking of the liquid-borne particle counter
Specifications
| Models |
Particle size (micron m) |
Nominal diameter (micron m) |
| CTX-0023 |
0.231 |
0.23 |
| CTX-0034 |
0.344 |
0.34 |
| CTX-0060 |
0.600 |
0.6 |
| CTX-0099 |
0.990 |
0.99 |
| CTX-0211 |
2.106 |
2 |
| CTX-0515 |
5.153 |
5 |
| CTX-1040 |
10.35 |
10 |
| CTX-1560 |
15.62 |
15 |
|