[Previouse] [Next] [Index] [Home]

Optional units for Liquid-born Particle Counters


Printer KP-06
Measurement condition, particle count by particle size, control of particle counter
  • Remote control of particle counter
  • The measurement values are recorded by the numerical values or bar graph. Average, maximum and minimum values are recorded.
  • Measurement conditions are also recorded.
  • Particle count change over time is recorded by bar graph.
  • Control of particle counter, unattended measurement possible

Printer for KC-01D1、03A1、18、20、22A、KL-20A、22、26、27
Specifications
Particle size ranges Max 6 channels (depending on the connected particle counter)
Measurement result printout items Date/time
Count for each size range (total only, or single and total, max. 7 digits for each)
Functions Selective printout of size ranges, Repeated measurement, Blank measurement, Automatic light source pause
Usable paper type TP-08 Thermal printer paper (58 mm X 30 m)
TP-10 Lint-free thermal printer paper (58 mm X 30 m)
Dimensions and Weight approx. 71 (H) X 170 (W) X 242 (D) mm, approx. 1.2 kg


Sensor Controller KZ-70
On-site monitor for multi-point monitoring system
KZ-70写真
  • Particle counter controller
  • Monitor on the spot
  • Three controller modes: Manual, Auto and Repeat
  • Particle size distribution: Max. 6 channels
  • Max. 300 m (extension) of sub-line cable available in controller mode
  • Max. 1000 m (extension) of bus-line cable available in monitor mode
Specifications
Available sensors KS-93, KS-16, KS-16F, KS-17, KS-17A, KA-80A, KA-81
Modes Monitor mode
Controller mode (Manual, Auto, Repeat)
Display items Date/Time,
Information of sensor (Node address, Model, Flow rate, updated condition of sensor), Measurement data (Sample volume, Error info, Particle size, Count),
Last measurement data (Count, Volume, Error info)
Particle size distribution Max. 6 channels
Dimensions and weight 170 (W) X 201 (D) X 60 (H) mm
Approx. 1.3 kg (main unit)


Pulse Height Analyzer KH-03
Monitoring size distribution and its change

The Pulse Height Analyzer KH-03 accepts an analog input signal from a particle counter and analyzes pulses comprised in this signal in real time. Signals are ranked by pulse height. The unit has a PHA mode for creating a pulse height based histogram, and an MCS mode for observing time-based fluctuations of pulse count.

KH-03写真

System configuration
  • A supplied probe for connection of the analog signal from the particle counter
  • The main unit which performs analysis of the signal from the probe
  • The Pulse Height Analyzer control software which controls the hardware and serves for data management
  • An adapter for connection between the main unit and the computer
  • A generic computer on which the control software is installed. (The computer is not supplied.)
Features
  • Monitoring the accuracy of Particle counter's particle size range (particle size resolution) and distribution performance
  • Confirming of the back ground level
  • Calculation of the more detail size distribution
  • Monitoring of particle count change over the long time measurement
Specifications
Input pulse detection frequency response 1kHz to 500kHz
Analysis voltage range 0〜64mV、128mV、256mV、512mV、1024mV、2048mV、4096mV、8192mV、16384mV、
Sample time 2, 10, 20, 50, 100, 250, 500, 1000 micro sec; selectable
Tolerance within +/-5%
Analysis modes PHA mode (pulse height analysis)
MCS mode (multi channel scaling)
Pulse count memory size 256ch
Absolute maximum input voltage range of Probe +/- 18V
Input impedance of Probe 1M ohm
Input capacitance 35 pF
Software Windows95, Windows98 (Using commercially available PC)
Dimensions and Weight Approx. 30 X 3.5 X 24 cm, Approx. 1.9 kg
 


Syringe Sampler KZ-30W1/KZ-30W2 (with CE marking)
Up to 50 sets of parameter settings can be stored in Purge or Measurement mode
KZ-30W写真
  • Choice of three operation modes: purge mode, measurement mode, and combination mode for preset sequence of purge and measurement operations.
  • Memory for up to 50 sets of parameter settings for purge mode or measurement mode.
  • Selectable blank volume lets sample fluid flow rate stabilize after start of plunger action.
  • Syringe set with integrated valve for easy replacement.
  • Automatic syringe capacity detection.
  • When the KZ-30W1/KZ-30W2 is used together with the Rion liquid-borne particle counter KL-11 etc., changing a setting that is common to both units (sample flow rate, blank volume, number of measurement cycles in the measurement mode) at one unit will automatically cause a change at the other unit as well, so that the setup of both units is matched.
  • The syringe sampler KZ-30W2 is in conformity with the European Union's CE Compliance requirements.

Specifications
Counters, sensors and syringe size can be connected
Counters and sensors KL-11, KL-11A, KL-20A, KL-22, KL-26, KL-27(with some limits regarding usable functions)
KS-40/40A/40AF/41, KE-40/40AKE-40 (with some limits regarding usable functions)
Syringe size 25 mL PP syringe set (standard)
25 mL Pylex glass syringe set (option)
10 mL Pylex glass syringe set (option)
Material of parts in contact with sample fluid: Material of parts in contact with sample fluid:
Suitable sample fluids: Fluids which do not cause corrosion of fluid-contacting parts
Operation stroke
Full stroke 66mm
Tolerance 60mm±2%
Repeat precision 0.5% or less
Resolution 0.6mm
Purge mode/Measurement mode
Flow rate
Setting range: 10 to 100mL/min (with 25 mL syringe set)
5 to 50mL/min (with 10 mL syringe set)
Resolution: 1mL/min
Purge/Measurement volume
Setting range: 0 to syringe capacity
Resolution: 1/100 of syringe capacity
Measurement blank volume 0 - 1/2.5 of syringe capacity
(Measurement volume + Blank volume < 1.1X syringe capacity)
Repeat setting 1to 99
Combination mode
Number of steps: 1 to 10
Number of memory addresses: 50 (with battery backup)
Combination mode memory: 1 (with battery backup)
Power Supply AC100-240 V, 50/60 Hz, Approx. 100 VA
Back-up Battery maxell SUPER Lithium ( model ER17-33 )
Dimensions and Weight Approx. 147 (W) X 350 (H) X 290 (D) mm, Approx. 6 kg


External Pressure Sampler KZ-30U/KZ-30MB
For off-line measurement, Sampler with pressure chamber
KZ-30MB写真 Particle counters can be connected:
KL-20, KL-20A, KL-21, KL-22, KL-26 and KL-27
  • The simple chemical-proof sampler, KZ-30U is designed to pressurize and supply sample fluid to the particle counters for off-line measurement.
  • Easy-to-operate chemical resistance sampler with chamber
  • When the pressure in the chamber is too high, exhaust the air in the chamber to prevent the malfunction.
Specifications
Maximum allowable input air pressure Sample air inlet: 0.4 MPa (gauge pressure)
Chamber: 0.2 MPa (gauge pressure)
Adjustable pressure range: 0.02 to 0.2 MPa (gauge pressure)
Maximum allowable valve pressure: 0.3 MPa (gauge pressure)
Material of parts in contact with sample fluid: PFA, PTFE, CTFE
Material of chamber: Pyrex glass (Inner surface is Teflon coated.),
SUS316, PP,
Chloroprene rubber
Dimensions and weight 674 (H) X 250 (W) X 400 (D) mm, Approx. 15 kg


Sampler using Dropping method KZ-30M3
Measurement for coarse particles and particles with high gravitation sedimentation velocity
Suitable models :KL-11, KS-60 series
  • For the measurement of particles with large size and high specific gravity which does not come in the sensor by usual forcing up method. Because their sedimentation velocity is too much high.
  • The sample fluid comes in through the funnel on the sensor. Measurement is carried out while the particles are falling.
Specifications
Sampling Dropping method
External pump KZ-28M1


Super Bellows Pump K9904
Supply sample fluid to particle counters without fluid leaks or contamination

This pump is designed for supplying sample fluid to liquid-borne particle counters. Because the pump uses the bellows principle, it has no plunger which could lead to fluid leaks or produce contamination.
Five different measurement modes are possible, to fit the requirements of various system configurations.
Pump Specifications
Pump principle Bellows
Sample object Photoresist, pure water, chemical fluids (no volatile fluids)
Max. exhaust volume 15 mL/stroke
Max. exhaust capacity 0.2 Mpa
Allowable fluid pressure 0.3 MPa
Min. fluid viscosity 30cp
Weight 3.2 kg
Controller Specifications
Operation start Auto start, manual start (pump only)
Intake rate switching 2 steps: purge and measurement
Connectors RS-232C-1, RS-232C-2, DATA LINK-1 X 2, DATA LINK-2, EXT CTRL-1, EXT CTRL-2, PUMP 1,2,3 (1 unit only)
Pump connection cable length Standard 1.5m, maximum 10 m
Power requirement 100 to 120 VAC
Dimensions 266.5 (W) X 181.5 (H) X 89.5 (D) mm (max.)


Flow controller CVR-PVC (for DI-water), CVR-1/4-FM (for Chemical solution)
Flow controller for in line measurement

CVR-1/4-FM
(Mass flow controller + Mass flow meter)

CVR-1/4-3
(Mass flow controller)
CVR-PVC and CVR-1/4-FM are flow controllers for Liquid-borne particle counter. They are located downstream of the counter in pressure line. They are made by SURPASS.

CVR-1/4-FM Specifications
Sample flow rate 8 to 15 mL/min
Connection PT1/4
Materials of parts exposed to sample fluid PTFE, PCTFE, High-purity Ceramic (SiC)
Allowable sample fluid temperature 10 to 70 C
Allowable sample fluid pressure 0.1 to 0.4 MPa, Max: 0.5 MPa


Portable Recirculation Filtration Unit MINIBOY<CHEMIBOY>
Cleaning of Particle Counter and easy blank check
MINIBOY写真
Pump: IWAKI MDG-M2S100
Joint: KURABO K fitter
Tube fitting: KURABO
Valve: Two-way tap 2C-30B
Filter: Mitsubishi Chemical CS09DN (one example)
Case material acrylic

Specifications
Dimensions 40(W) X 29(H) X 15 (D)cm
Power supply AC100V+/-10% 50/60 Hz. 0.5 A


●Chemical Solution Recirculation Filtration Unit CHEMIBOY
Recirculate and filtrate the sample fluid to maintain its cleanliness and supply it to the particle counter
Specifications
Main unit material stainless steel
Material of parts in contact with sample fluid PTFE, PFA, PP, polyolefin, SUS316
Max. filtrate particle size 0.09micorn m
Max. flow rate 8 L/mine
Max allowable pressure 3.0 Kgf/cm2
Temperature for operation 20C
Dimensions and weight 350(W) X 250 (H) X 250 (D) mm, 10 kg


Concentrations-standard fluid CLINTEX
An exclusive, concentrations-standard suspension of a size-standard particle for calibration management
クリンテックス写真
  • Monodispersed PSL suspension by 1000 particles/mL
  • Accuracy of particle size and its distribution;
    accuracy of size: Indicated value +/- 3%
  • On-site checking of the liquid-borne particle counter
Specifications
Models Particle size (micron m) Nominal diameter (micron m)
CTX-0023 0.231 0.23
CTX-0034 0.344 0.34
CTX-0060 0.600 0.6
CTX-0099 0.990 0.99
CTX-0211 2.106 2
CTX-0515 5.153 5
CTX-1040 10.35 10
CTX-1560 15.62 15



[Previouse] [Next] [Index] [Home]